superheat    
vt. 使过热
n. 过热

使过热过热

Superheat \Su`per*heat"\, v. t. [imp. & p. p. {Superheated}; p.
pr. & vb. n. {Superheating}.]
1. To heat too much, to overheat; as, to superheat an oven.
[1913 Webster]

2. (Steam Engine) To heat, as steam, apart from contact with
water, until it resembles a perfect gas.
[1913 Webster]

3. To heat (a liquid) above its boiling point without
converting it into vapor.
[Webster 1913 Suppl.]


Superheat \Su"per*heat`\, n.
The increase of temperature communicated to steam by
superheating it.
[1913 Webster]


请选择你想看的字典辞典:
单词字典翻译
superheat查看 superheat 在百度字典中的解释百度英翻中〔查看〕
superheat查看 superheat 在Google字典中的解释Google英翻中〔查看〕
superheat查看 superheat 在Yahoo字典中的解释Yahoo英翻中〔查看〕





安装中文字典英文字典查询工具!


中文字典英文字典工具:
选择颜色:
输入中英文单字

































































英文字典中文字典相关资料:


  • EWAD960C Daikin Chiller – Low Discharge Superheat Alarm. . .
    EWAD960C Daikin Chiller – Low Discharge Superheat Alarm Issue (air cooled screw compressor) Hello everyone, I’m dealing with an issue on a Daikin EWAD960C chiller after the compressor was replaced about a year ago The problem I’m facing is a low discharge superheat alarm, which occurs approximately once a week Steps I’ve Taken So Far: 1
  • York chiller yvaa low discharge superheat - HVAC-Talk
    York chiller yvaa low discharge superheat 1 reading Jump to Latest 3 1K views 5 replies 3 participants last post by jayguy Jul 1, 2024
  • best way to check superheat - HVAC-Talk
    Evaporator Superheat Check Your Superheat After the box temperature has reached or is close to reaching the desired temperature, the evaporator superheat should be checked and adjustments made if necessary Generally, systems with a design TD of 10¢ªF should have a superheat value of 6¢ª to 10¢ªF for maximum efficiency For systems
  • Discharge Superheat - HVAC-Talk
    Sometimes referred to as compressor superheat, total superheat consists of evaporator superheat plus suction line superheat A technician can measure total superheat by placing a thermistor or thermocouple at the compressor's inlet and taking the temperature
  • HeatPump superheat - HVAC-Talk
    Superheat reading Again, everyone tells us where to take superheat readings, but no one gives a number that should be used for insuring the charge is correct If you take the superheat at the evap coil, the superheat will be lower - what number would you set by?
  • high superheat with normal subcooling on trane straight cool
    You could check your evap superheat to see if you are maintaining a better superheat at the outlet than at the condenser but you are still under 32 with your saturation temp so you need to increase pressure in the evap either by increased airflow or adding additional refrigerant
  • Setting superheat on TXVs - HVAC-Talk
    My system (R22) is running 59 psi low 150psi high 59* suc line temp and 78* liq line temp so 26* of superheat and 5* subcooling OAT is 74* but feels more like 90 with the humidity which I have no real way to check but Metasys says 96% per OAH sensor
  • Discharge Superheat - HVAC-Talk
    discharge superheat is one of my favorite topics and checks it is the sum accumulation of the entire refrigeration system but, at the end of the day, it isn't a directly adjustable measurement no valve no knob nothing to adjust
  • High Superheat, Normal Subcooling - HVAC-Talk
    High superheat is right when you have a heavy load, but that doesn't reflect the normal subcooling at such a high head pressure Filter-Drier, if you have one, may be clogged