英文字典中文字典


英文字典中文字典51ZiDian.com



中文字典辞典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z       







请输入英文单字,中文词皆可:


请选择你想看的字典辞典:
单词字典翻译
153895查看 153895 在百度字典中的解释百度英翻中〔查看〕
153895查看 153895 在Google字典中的解释Google英翻中〔查看〕
153895查看 153895 在Yahoo字典中的解释Yahoo英翻中〔查看〕





安装中文字典英文字典查询工具!


中文字典英文字典工具:
选择颜色:
输入中英文单字

































































英文字典中文字典相关资料:


  • Electric Distribution Line Guying Guide | PDF - Screw
    This document provides guidelines for designing guy assemblies and anchors for wood distribution poles It lists standard Rural Utilities Service guy and anchor assemblies, including their permitted loads and holding power
  • RUS Bulletin 1724E-153 - Rural Development
    PURPOSE: This guide bulletin provides information needed to properly design guying for conductors attached to wood distribution poles To this end, the bulletin contains data, equations, and sample calculations
  • UTILITY LINE DESIGN CALCULATIONS
    The following calculations are included in the website, requires minimal training and take seconds to perform Utility Line Design has over twenty-five planned calculations that will be added to the website at no added charge in the coming months
  • Pole Guying: NESC, RUS Standards Grounding - studylib. net
    Learn about pole guying, NESC RUS standards, guy factors, grounding in electrical distribution Ideal for engineers technicians
  • Guying of Poles - tpub. com
    With this type of guy, the wire is run from the top of the pole to an anchor in the ground Some common uses of the down guys areas follows: a SIDE GUY A side guy (fig 2-8) is used to reinforce a pole line against an unbalanced side pull of the conductors Such pulls are developed at curves, angles, or sharp turns in the line
  • GUYING 11 00 03 01 Chart for Selection of Guy Strand - Ameren
    Determine the height over lead ratio H L = 32 10=3 2 (Radial Line) 0 04 02, the conductor tension is 482 lbs for 1 0 Locate this value on vertical scale of chart on Figure 1 and project this value horizontally to the right to the inter-section with radial line 3 2
  • A Detailed Guide to Guy Wires – Function, Design and Maintenance
    Guy wire design depends on the weight, height and expected wind load of the structure Number of guy wires needed and the optimal angles are calculated For even support, guy wires are normally put in at 120 degree angles The diameter of wire is chosen according to the required tensile strength
  • Design of Guyed Electrical Transmission Structures
    This publication describes the various types of guyed structures that have been used; presents typical guys and fittings; illustrates guy anchors and foundations; explores analysis and design techniques specific to guyed structures; discusses unique construction and maintenance problems; and displays both hand and computer calculations to
  • Overhead Design Illustrations: Down Guys
    The attachment height refers to the height at which the guy wire is attached to the pole Down guys can be attached to both the pole as well as the crossarm in the event that a crossarm is uneven
  • Guying Software - LineDesign Engineering
    The guys tab allows a user to enter existing or proposed guy information, to model their effect on pole loading (transverse vertical) The results of the forces moments due to these guy wires are transferred to the calculation, sum, and buckle tabs





中文字典-英文字典  2005-2009